PD Dr. med. dent. Goran I. Benic
Oberarzt
|
|
Clinical Specialisations
Specialist in Reconstructive Dentistry, Swiss Society of Reconstructive Dentistry
Research Interests
- Fixed and removable implant and tooth supported reconstructions
- Bone and soft tissue augmentation procedures
- Esthetics in reconstructive dentistry
- Digital workflow in reconstructive dentistry
- Clinical applications of CBCT imaging
Selected publications
Benic GI, Jung RE,
Siegenthaler DW, Hämmerle CHF
Clinical and radiographic comparison of implants in regenerated or native bone:
5-year results. Clinical Oral Implants Research, 2009, 20: 507-513
Benic GI, Mokti M, Chen C-J,
Weber H-P, Hämmerle CHF, Gallucci GO
Dimensions of buccal bone and mucosa at immediately placed implants after 7
years: a clinical and cone beam computed tomography study. Clinical Oral
Implants Research, 2012, 23: 560-566
Benic GI, Wolleb K,
Sancho-Puchades M, Hämmerle CHF
Systematic Review of parameters and methods for the professional assessment of
aesthetics in dental implant research. Journal of Clinical Periodontology,
2012, 39 (Suppl 12): 160-192
Benic GI, Gallucci GO, Mokti
M, Hämmerle CHF, Weber HP, Jung RE
Titanium-zirconium
narrow-diameter versus titanium regular-diameter implants for anterior and
premolar single crowns: 1-year results of a randomized controlled clinical
study. J Clinical Periodontology,
2013, 40: 1052-1061
Benic GI, Wolleb K, Hämmerle
CHF, Sailer I
Effect of the color of
intra-radicular post on the color of buccal gingiva: a clinical
spectrophotometric evaluation.
International Journal
Periodontics & Restorative Dentistry, 2013, 6: 733-741
Benic GI, Mir-Mari J, Hämmerle
CHF
Loading protocols for single
implant crowns: a systematic review and meta-analysis. Int J Oral & Maxillofac
Implants, Accepted for publication
Links
Publications in ZORA (Zurich Open Repository and Archive)
ZORA Publication List
Download Options
Publications
-
Clinical Performance of Monolithic Zirconia Crowns on Titanium–Zirconium Reduced‐Diameter Implants in the Molar Area : Interim Data at Three Years of a Randomized Controlled Trial. Clinical Oral Implants Research, 34(12):1354-1362.
-
Computer‐assisted bone augmentation, implant planning and placement: An in vitro investigation. Clinical Oral Implants Research, 34(7):719-726.
-
Soft-tissue dimensional change following guided bone regeneration on peri-implant defects using soft-type block or particulate bone substitutes: 1-year outcomes of a randomized controlled clinical trial. Journal of Clinical Periodontology, 50(2):147-157.
-
Vertical bone augmentation using collagenated or non-collagenated bone substitute materials with or without recombinant human bone morphogenetic protein-2 in a rabbit calvarial model. Journal of Periodontal & Implant Science, 53(6):429-443.
-
Randomized controlled clinical trial comparing guided bone regeneration of peri-implant defects with soft-type block versus particulate bone substitutes: Six-month results of hard-tissue changes. Journal of Clinical Periodontology, 49(5):480-495.
-
Effect of collagen membrane and of bone substitute on lateral bone augmentation with titanium mesh: An experimental in vivo study. Clinical Oral Implants Research, 33(4):413-423.
-
Trueness of intraoral scanners in digitizing specific locations at the margin and intaglio surfaces of intracoronal preparations. Journal of Prosthetic Dentistry, 126(6):779-786.
-
Effectiveness of xenogeneic and synthetic bone-block substitute materials with/without recombinant human bone morphogenetic protein-2: A preclinical study using a rabbit calvarium model. Journal of Clinical Periodontology, 48(8):1126-1136.
-
Relationship between internal accuracy and load-bearing capacity of minimally invasive lithium disilicate occlusal veneers. International Journal of Prosthodontics, 34(4):365–372.
-
Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies. Scientific Reports, 11:2606.
-
Prosthetic outcomes and clinical performance of CAD-CAM monolithic zirconia versus porcelain-fused-to-metal implant crowns in the molar region: 1-year results of a RCT. Clinical Oral Implants Research, 31(9):856-864.
-
Histologic Outcomes After Guided Bone Regeneration of Peri-implant Defects Comparing Individually Shaped Block Versus Particulate Bone Substitutes. International Journal of Periodontics and Restorative Dentistry, 40(4):519-527.
-
Trueness of digital intraoral impression in reproducing multiple implant position. PLoS ONE, 14(11):e0222070.
-
Hard tissue changes after guided bone regeneration of peri-implant defects comparing block versus particulate bone substitutes: 6-month results of a randomized controlled clinical trial. Clinical Oral Implants Research, 30(10):1016-1026.
-
Load-bearing capacities of ultra-thin occlusal veneers bonded to dentin. Journal of the Mechanical Behavior of Biomedical Materials, 95:165-171.
-
Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part III: Marginal and internal fit. Journal of Prosthetic Dentistry, 121(3):426-431.
-
Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination. Clinical Oral Implants Research, 29(12):1195-1201.
-
Ultra-thin occlusal veneers bonded to enamel and made of ceramic or hybrid materials exhibit load-bearing capacities not different from conventional restorations. Journal of the Mechanical Behavior of Biomedical Materials, 90:433-440.
-
Clinical Performance of Dental Implants Following Sinus Floor Augmentation: A Systematic Review and Meta-Analysis of Clinical Trials with at Least 3 Years of Follow-up. International Journal of Oral & Maxillofacial Implants, 33(3):e46-e65.
-
A strain gauge analysis comparing 4-unit veneered zirconium dioxide implant-borne fixed dental prosthesis on engaging and non-engaging abutments before and after torque application. Clinical and Experimental Dental Research, 4(1):13-18.
-
Clinical quality and efficiency of monolithic glass ceramic crowns in the posterior area: digital compared with conventional workflows. International Journal of Computerized Dentistry, 21(3):215-223.
-
Effect of Different Intraradicular Posts on the Color of the Buccal Gingiva at Teeth Restored with Zirconia Crowns. International Journal of Periodontics and Restorative Dentistry, 38(1):71-78.
-
A Randomized Controlled Clinical Trial Comparing Conventional and Computer-Assisted Implant Planning and Placement in Partially Edentulous Patients. Part 1: Clinician-Related Outcome Measures. International Journal of Periodontics and Restorative Dentistry, 38(Suppl):s49-s57.
-
Clinical and histologic evaluation of different approaches to gain keratinized tissue prior to implant placement in fully edentulous patients. Clinical Oral Investigations, 22(5):2111-2119.
-
Volumetric and linear changes at dental implants following grafting with volume-stable three-dimensional collagen matrices or autogenous connective tissue grafts: 6-month data. Clinical Oral Investigations, 22(3):1185-1195.
-
Guided bone regeneration at zirconia and titanium dental implants: a pilot histological investigation. Clinical Oral Implants Research, 28(12):1592-1599.
-
Primary ridge augmentation with collagenated xenogenic block bone substitute in combination with collagen membrane and rhBMP-2: a pilot histological investigation. Clinical Oral Implants Research, 28(12):1543-1552.
-
Randomized controlled clinical trial comparing one-piece and two-piece dental implants supporting fixed and removable dental prostheses: 4- to 6-year observations. Clinical Oral Implants Research, 28(12):1553-1559.
-
Guided bone regeneration with particulate vs. block xenogenic bone substitutes: a pilot cone beam computed tomographic investigation. Clinical Oral Implants Research, 28(11):e262-e270.
-
Digital technique for in vivo assessment of internal and marginal fit of fixed dental prostheses. Journal of Prosthetic Dentistry, 118(4):452-454.
-
Clinical and radiographic intra-subject comparison of implants placed with or without guided bone regeneration: 15-year results. Journal of Clinical Periodontology, 44(3):315-325.
-
Effect of ridge preservation for early implant placement - is there a need to remove the biomaterial?. Journal of Clinical Periodontology, 44(5):556-565.
-
Severe tooth wear: European Ccnsensus statement on management guidelines. Journal of Adhesive Dentistry, 19(2):111-119.
-
Soft tissue volume augmentation at dental implant sites using a volume stable three-dimensional collagen matrix – histological outcomes of a preclinical study. Journal of Clinical Periodontology, 44(2):185-194.
-
Influence of wound closure on the volume stability of particulate and non-particulate GBR materials: an in vitro cone-beam computed tomographic examination. Part II. Clinical Oral Implants Research, 28(6):631-639.
-
Randomized controlled within-subject evaluation of digital and conventional workflows for the fabrication of lithium disilicate single crowns. Part III: marginal and internal fit. Journal of Prosthetic Dentistry, 117(3):354-362.
-
Spectrophotometric and visual evaluation of peri-implant soft tissue color. Clinical Oral Implants Research, 28(2):192-200.
-
Guided bone regeneration and abutment connection augment the buccal soft tissue contour: 3-year results of a prospective comparative clinical study. Clinical Oral Implants Research, 28(2):219-225.
-
Volumetric analysis of chin and mandibular retromolar region as donor sites for cortico-cancellous bone blocks. Clinical Oral Implants Research, 27(8):999-1004.
-
Guided bone regeneration of peri-implant defects with particulated and block xenogenic bone substitutes. Clinical Oral Implants Research, 27(5):567-576.
-
Accuracy of Three-Dimensional Printed Templates for Guided Implant Placement Based on Matching a Surface Scan with CBCT. Clinical Implant Dentistry and Related Research, 18(4):762-768.
-
Marginal bone-level alterations of loaded zirconia and titanium dental implants: an experimental study in the dog mandible. Clinical Oral Implants Research, 27(4):412-420.
-
Influence of blinded wound closure on the volume stability of different GBR materials: an in vitro cone-beam computed tomographic examination. Part I. Clinical Oral Implants Research, 27(2):258-265.
-
Prospective randomized controlled clinical study comparing two dental implant types: volumetric soft tissue changes at 1 year of loading. Clinical Oral Implants Research, 27(4):406-411.
-
Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study.. Journal of Clinical Periodontology, 42(11):1060-1070.
-
In vitro assessment of artifacts induced by titanium, titanium-zirconium and zirconium dioxide implants in cone-beam computed tomography. Clinical Oral Implants Research, 26(10):1222-1228.